Florida Pollutant Storage Systems Contractor License

Updated October 2026

Pollutant storage systems contractors install, repair and remove the tanks, piping and dispensing equipment used to store fuel and other regulated pollutants. It is a statutory Division II category, and the work is governed by Florida Department of Environmental Protection (DEP) tank rules as well as the Construction Industry Licensing Board (CILB).

What the license covers

F.S. 489.105(3)(p) defines the contractor as one "whose services are limited to, and who has the experience, knowledge, and skill to install, maintain, repair, alter, extend, or design, if not prohibited by law," pollutant storage tanks. Anyone installing a pollutant storage tank must follow the standards adopted under F.S. 376.303.

Two related definitions in the same section:

The DEP connection

CILB rule 61G4-15.027 adopts DEP rule chapter 62-761 as the board's operating standards for pollutant storage system specialty contractors and says the board's rules do not override DEP's standards. In practice you work to both.

The CILB rule chapter also has separate rules for precision tank testers (61G4-15.028) and tank lining applicators (61G4-15.029).

Certified vs registered

Certified contractors may contract statewide; registered contractors only where they met local competency requirements (F.S. 489.105(8), (10)).

Eligibility

F.S. 489.111(2): age 18, good moral character, and an experience route (4 years as a skilled worker or foreman with 1 year as foreman, a relevant degree plus 1 year, or a listed combination with college credit).

The exams

Exam Scored questions Time Passing score
Business and Finance 120 6.5 hours 70%
Pollutant Storage trade knowledge 80 5 hours 70%

Content outline

Area Topic Share
A Pre-installation and site preparation 7%
B Material handling 5%
C Excavating 10%
D Supports and anchorage 7%
E Backfill 10%
F Tank installation 12%
G Piping, valves and fittings 14%
H Above tank covering 5%
I Leak detection 10%
J Cathodic protection systems 5%
K Tank removal and abandonment 10%
L Equipment 5%

Reference list overview

Exam volume

Pearson VUE exam performance reports show 11 graded pollutant storage attempts in 2025 and 7 in 2024. It is one of the smallest CILB exams.

Steps

  1. Document tank installation experience under 489.111.
  2. Register with Professional Testing, Inc.; schedule both exams at Pearson VUE.
  3. Pass both at 70%.
  4. Apply to the CILB, and confirm any separate DEP requirements for your work.

FAQ

Do aboveground tanks count? The statutory definition of "tank" excludes containers that are aboveground and elevated or on an impermeable surface where a leak would be readily detected. Aboveground systems are still on the exam (PEI RP200), so check the specific tank against the definitions and DEP rules.

Is tank removal covered? Yes. Tank removal and abandonment is 10% of the exam.

Who regulates the installation standards? DEP. Rule 61G4-15.027 adopts chapter 62-761 as the board's operating standards.

Next step

Pollutant storage candidates also take the Business and Finance exam. Prepare with our Florida Business and Finance Exam Prep.

Sources

National Trades Institute
An independent test-preparation provider. Not a school, and not affiliated with or endorsed by any state licensing board, DBPR, NASCLA, or Pearson VUE.  ·  Privacy  ·  Terms  ·  Refunds  ·  Contact